Precautions for programming
To enable the interruption of the unit, the interruption to the CPU unit must be enabled using
the El instruction.
When a unit in which interruption occurs is not installed in the specified slot, an operation
error occurs.
When there is no definition of the interruption program (INTPG) corresponding to an enabled
bit, the bit is not enabled. Zero is written.
Flag operations
Name Description
SR7
SR8
(ER)
ON in the case of out-of-range in indirect access (index modification)
3.41 IMASK (Unit Interruption Disable/Enable Setting)