The relative address storage position ([D]+[n]) varies with the operation unit.
The maximum amount of data that can be specified is 30000.
[D] is in the following format according to the operation unit.
Operation
unit
16 bits (US, SS) 32 bits (UL, SL, SF) 64 bits (DF)
Output content
Device
size
16 bit 32 bit 16 bit 32 bit 16 bit 32 bit
Result
storage
area
[D]
Cannot
specify
[D] to [D
+1]
[D]
[D] to [D
+3]
[D] to [D
+1]
Stores the maximum
value.
[D+1] to [D
+2]
Cannot
specify
[D+2] to [D
+3]
[D+1]
[D+4] to [D
+5]
[D+2]
Position of the first
detected maximum
value. Relative
position with the start
of [S1] as 0.
10.3 MAX (Acquiring the Maximum Value)