EasyManuals Logo

Panasonic FP7 Series Command Reference Manual

Panasonic FP7 Series
1222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #464 background imageLoading...
Page #464 background image
The relative address storage position ([D]+[n]) varies with the operation unit.
The maximum amount of data that can be specified is 30000.
[D] is in the following format according to the operation unit.
Operatio
n unit
16 bits (US, SS) 32 bits (UL, SL, SF) 64 bits (DF)
Output content
Device
size
16 bit 32 bit 16 bit 32 bit 16 bit 32 bit
Result
storage
area
[D]
Cannot
specify
[D] to [D
+1]
[D]
[D] to [D
+3]
[D] to [D
+1]
Stores the minimum
value
[D+1] to [D
+2]
Cannot
specify
[D+2] to
[D+3]
[D+1]
[D+4] to
[D+5]
[D+2]
Position of the first
detected maximum
value. Relative
position with the
start of [S1] as 0.
10.4 MIN (Acquiring the Minimum Value)
10-14 WUME-FP7CPUPGR-12

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals