SF2.617994E01
SF0.000000E00
SF0.000000E00
Value
Example) Operation unit: Single-precision, floating-point real number (SF) (Designate 15SIN value
for [S])
[S]…DT10 [D]…DT2
DT10DT11
DT12DT13
DT14DT15
[i]…SF
DT0DT1
DT2DT3
DT4DT5
Angle
Value (radians)
SF2.588190E01
SF1.047198E00
SF1.570796E00
15
30
45
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when a non-real number is specified for [S] (angle data).
To be set when [S] (angle data) is out of the accessible range.
11.4 ASIN (Arcsine Operation)
11-10 WUME-FP7CPUPGR-12