EasyManuals Logo

Panasonic FP7 Series Command Reference Manual

Panasonic FP7 Series
1222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #613 background imageLoading...
Page #613 background image
Processing
K 347100859
[S]…DT0 [D]…DT10
* 2 words* 1 word
K 1
K 1
(year)
(month)
(day)
(hours)
(minutes)
(seconds)
K 12
K 8
DT0
DT1
DT2
DT3
DT4
DT5
K 54
K 19
(Source seconds data)
DT10DT11
Example) Calculate seconds data against the base time, from 08:54:19, January 1, 2012
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when the clock data range is exceeded.
12.5 TMSEC (Calculation: Clock Data → Seconds Data from the Base Time)
WUME-FP7CPUPGR-12 12-11

Table of Contents