[S1]...U0 [S2]...U0 [S3]...U400 [D]...DT0
Precautions for programming
[S1] is always zero. An operation error occurs when numbers other than zero are specified.
Specify [S3] to be larger than [S2].
When [S3] exceeds the upper limit of the system area, an operation error does not occur.
The area from [S2] to the upper limit of the system area is copied.
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when [S1] is other than 0.
To be set when [S2] is larger than [S3].
To be set when [S2] is out of the accessible range.
To be set when the destination range is outside the accessible range.
13.10 SCOPY (System Area Copy)
WUME-FP7CPUPGR-12 13-17