Example) Comparing strings "ABCD" and "ABCDE", which are stored in the data
register
[S1]...DT0 [S2]...DT10 SRA...OFF SRB...OFF SRC...ON
(1) Character count
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when the string range specified by [S1] or [S2] is out of the accessible range.
SRA (>)
Depending on the comparison resultSRB (=)
SRC (<)
14.16 SCMP (String Compare)