PM Tables
SM 4-1 D093/D094
Preventive
Maintenance
4. PREVENTIVE MAINTENANCE
4.1 PM TABLES
Key for the PM Table
A = Adjust, C = Clean, I = Inspect, L = Lubricate, R = Replace
Units of measure in the PM Interval column: Metric: 1,000 meters, Feet: 1,000 feet
4.1.1 MAIN MACHINE (D093/D094)
Description Q’ty
PM Interval
PM Comments
Metric Feet
Scanner
Original Feed Rollers 5.5 18.0 C Damp cloth
Original Exit Rollers 5.5 18.0 C
Platen White Plate 5.5 18.0 C
Original Width, Set,
Registration, Exit Sensors
33.0 108.0 C Blower brush
Exposure Glass 5.5 18.0 C Damp cloth or glass
cleaner
CIS Surfaces 5.5 18.0 C Alcohol or lens paper
Development
Developer (1000 g) 2 27.5 90.0 R Replace if necessary.
(
p.5-41)
Development Filter 5.5 18.0 C Dry cloth or vacuum
cleaner
Development Roller Gear 5.5 18.0 I