Main SP Modes
SM 6-15 D093/D094
System
Maintenance
Reference
SP2-xxx Drum
2001 Charge Corona Adjustment
This SP adjusts the charge corona outputs.
2 Grid Voltage: Image Area
Adjusts the charge grid output.
[160 to 1080/800/1
A step]
2101 Print Erase Margin
Adjusts the quantity of erase for copy mode (quantity of white space).
1 Leading Edge
[0 to 10 / 2 /0.1 mm step]
2 Trailing Edge
3 Left edge
4 Right edge [0 to 10/ 0.5 / 0.5 mm step]