SP1-xxx Feed
SM Appendix 2-23 D093/D094
Appendix:
SP Mode
Tables
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
1937 Low Temp Environ Detect Ctrl
These SP's are used to modify fusing temperature control sequence in a low
temperature environment where room temperature is below the optimum room
temperature of 20
o
C (68
o
F).
Note
At optimum room temperature, the machine should reach the target fusing
temperature within 2 min.
If the hot roller does not reach the target fusing temperature within 4.5
minutes, the machine issues SC542 (Fusing Temperature Warmup Error).
2 Low Temp Time Setting
This SP sets the length of time within which the hot roller temperature should
reach 140°C. If the hot roller does not reach 140°C within this time limit, copying
cannot start until the hot roller reaches its target temperature.
[0 to 120/85/1 sec.]
3 Pressure Inching Start: Temp
If the inching target temperature (set with SP1948) is higher than 65
o
C, inching
will start when the hot roller temperature reaches this target hot roller
temperature. If the pressure roller temperature is less than 60
o
C, inching will
start at the ready (reload) temperature.
This SP sets the temperature at which inching starts in a low-temperature
environment where fusing temperature control is handled with the settings of
SP1937.
[0 to 50/20/5]
11 Low Temp Mode Setting: Cold Start
If the hot roller temperature is below the temperature set with this SP at the