Special Adjustments
SM 5-105 D093/D094
Replacement
and
Adjustment
Step 3: Magnification for Paper Type: Translucent
1. Make a 1:1 copy of the A0 SEF Magnification Chart with translucent (tracing) paper.
You can use a different test chart, if it has lines 1000 mm long in the sub-scan
direction and 700 mm long in the main-scan direction.
2. Measure the length and width of the images on the original and the copy.
3. Do the same measurements that you did for “Step 1: Magnification for Paper Type: Plain”.
4. Do these SPs in the sequence shown in this table, if the measurements are not in the
standard range:
SP Standard Fine Magnification
2916-3 Less than ±0.5 Translucent: Mode 1-4: Main Scan
2916-4 Less than ±0.5 Translucent: Mode 1-4: Sub Scan
Step 4: Magnification for Paper Type: Film
1. Make a 1:1 copy of the A0 SEF Magnification Chart with film.
You can use a different test chart if it has lines 1000 mm long in the sub-scan
direction and 700 mm long in the main-scan direction.
2. Measure the length and width of the images on the original and the copy.
3. Do the same measurements for “Magnification for Paper Type: Plain”.
4. Do these SPs in the sequence shown in this table, if the measurements are not in the
standard range:
SP Standard Fine Magnification
2916-5 Less than ±0.5 Film: Mode 1-4: Main Scan
2916-6 Less than ±0.5 Film: Mode 1-4: Sub Scan