Loading...
Main SP Modes
D093/D094 6-62 SM
3
Function Flag
Enables and disables remote diagnosis over the @Remote network.
[0 to 1/0/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
7
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the @Remote over a network intersection.
[0 to 1/0/1]
0: Yes. SSL not used.
1: No. SSL used.
8
RCG Connect Timeout
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the @Remote network.
[1 to 90/30/1 sec.]
9
RCG Write to Timeout
Sets the length of time (seconds) for the time-out when sent data is written to the
RCG during a call over the @Remote network.
[0 to 100/60/1 sec.]
10
RCG Read Timeout
Sets the length of time (seconds) for the timeout when sent data is written from
the RCG during a call over the @Remote network.
[0 to 100/60/1 sec.]
11
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80
on the @Remote network.
[0 to 1/0/1]
0: No. Access denied
1: Yes. Access granted.