SP5-xxx Mode
D093/D094 2-118 SM Appendix
5416 Access Information
1 Access User Max Number
Limits the number of users used by the access exclusion and password
attack detection functions.
[50 to 200/200/1 users]
2 Access Password Max Number
Limits the number of passwords used by the access exclusion and
password attack detection functions.
[50 to 200/200/1 passwords]
3 Monitor Interval
Sets the processing time interval for referencing user ID and password
information.
[1 to 10/3/1 sec.]
5417 Access Attack
1 Access Permissible Number
Sets a limit on access attempts when an excessive number of attempts are
detected for MFP features.
[0 to 500/100/1]
2 Attack Detect Time
Sets the length of time for monitoring the frequency of access to MFP
features.
[10 to 30/10/1 sec.]
3 Productivity Fall Wait
Sets the wait time to slow down the speed of certification when an
excessive number of access attempts have been detected.
[0 to 9/3/1 sec.]