Development
D093/D094 5-40 SM
5.4 DEVELOPMENT
5.4.1 DEVELOPMENT UNIT
Preparation
Raise the upper unit. (
p.5-7 "Raising and Locking the Scanner Unit")
Remove:
Side covers (
p.5-2 "Side Covers")
Toner hopper cover (
p.5-8 "Toner Hopper Cover")
Idle registration roller panel (
p.5-9 "Idle Registration Roller Panel")
Toner cartridge
1. On the left side:
Disconnect the left end of the development unit [A] (
x2, x1, x1).
Remove the screws [B] (
x1, x1).
2. On the right side:
Disconnect the right end of the development unit [C] (
x2, x1, x1).
Remove the screws [D] (
x1, x1).
3. Remove the development unit [E].
The development unit is very heavy. Pull it out slowly.
Re-installation
Re-attach the large shoulder screws on each side first, then re-attach the other screws.