SP4-xxx Scanner
SM Appendix 2-87 D093/D094
Appendix:
SP Mode
Tables
4724
Black Level Data DFU
Displays the minimum value for black level correction for each CIS unit after
black level is adjusted after power on.
[0 to 1023 / 0 / 1]
1 CIS 1
2 CIS 2
3 CIS 3
4 CIS 4
5 CIS 5
4732
CIS Gain Adjustment DFU
Displays the gain value of analog ASIC (LM98714) of each CIS unit after white
level is adjusted when the machine is powered on.
The peak value for standard white plate reading (the shading data peak
value) is set to 880 ±20 digits by white level adjustment.
The setting can be written with this SP and the set value is reflected in the
analog ASIC (LM98174) of the CIS when an original is scanned.
[0 to 255 / 84 / 1]
1 CIS 1
2 CIS 2
3 CIS 3
4 CIS 4
5 CIS 5