Main SP Modes
D093/D094 6-34 SM
SP3-xxx Process Control
3001 ID Sensor Initial Setting
These SP's do the settings for the ID sensor LED.
1
PWM Setting: ID Sensor LED DFU
Sets the level of the PWM (Pulse Width Modulation) of the ID sensor LED.
[0 to 100/20/0.1%]
2 Initialize ID Sensor: Execute
Automatically adjusts the ID sensor with a sensor reading of the bare drum. The
initial setting is 4.0V ±0.2. This SP requires about 4 sec. to execute. Always do
this SP at installation, and after you replace these components:
OPC Drum
ID Sensor
NVRAM
MCU