EasyManua.ls Logo

Ricoh D093 - Cis

Ricoh D093
779 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scanner
D093/D094 5-20 SM
5.2.6 CIS
Before You Begin…
To preserve the alignment of its components and to prevent other damage, always handle
the CIS unit carefully to protect it from sudden shock and vibration.
To prevent finger prints and smudges, never touch the CIS lens cover with bare hands.
Clean the CIS lens cover with lens paper only. Never use tissue paper or cloth that could
leave lint or other particles on the glass.
To preserve the alignment of its components, always disconnect and re-connect the CIS
unit at the SIF. Never disconnect the signal or power supply harnesses from the CIS unit.
Preparation
Remove the left and right upper side covers. (
p.5-2 "Side Covers")
Unlock and raise the original unit. (
p.5-5 "Unlocking, Opening the Original Unit")
Raise and lock the scanner unit and remove the original table. (
p.5-7 "Raising and
Locking the Scanner Unit")
1. At the rear, open the clamps on the lower plate (
x16).