Service Call Tables
SM 7-23 D093/D094
Trouble-
Shooting
541 A Fusing Thermistor Errors
The thermistor measured the hot roller temperature every 1 sec. for 30 sec.
and the temperature remained below 5
o
C (54
o
F).
Thermistor positioned incorrectly
Thermistor cable loose, disconnected, damaged
Thermistor defective
542 A Fusing Temperature Warm-up Error
The hot roller did not reach the ready temperature within 4 min. 30 sec. after
power on.
-or-
The hot roller did not reach 100°C within 130 sec. after power on.
Fusing lamp connections loose, broken, defective
Fusing lamp defective
Thermistor not touching the hot roller
Thermistor defective
MCU defective
The ready temperature is determined by the state of the machine at
recovery:
Ready Temp. = Target Fusing Temp. (if power on or recovery starts
when the hot roller is 80°C or higher).
Ready Temp. = Target Fusing Temp. – 10°C (SP1105-1 default) if power
on or recovery starts when the hot roller is less that 80°C.
Ready Temp. = Target Fusing Temp. – 20°C (SP1937-3 default) if power
on or recovery starts with pressure roller inching control on.