5.5.3 ID SENSOR, PICK-OFF PAWLS, PICK-OFF PAWL SOLENOID
1. Drum ( p.5-47 "Drum Unit")
2. Cleaning blade (
p.5-50 "Cleaning Blade")
3. ID sensor [A] (
x 3, x 1, x 1)
4. Pick-off pawls (x2) [B] (pressure release).
5. Pick-off pawl solenoid [C] (
x 2, x 1)
Re-installation
After replacing or cleaning the ID sensor, do SP3001-2 to initialize the new ID sensor.
If the ID sensor is damaged and cannot be replaced immediately, set SP2208-3 (Toner
Supply Setting: Toner Supply Mode) to “1”. Then the customer can continue to use the
machine until a new ID sensor is available. After you install a new ID sensor, reset this SP