SP1-xxx Feed
SM Appendix 2-31 D093/D094
Appendix:
SP Mode
Tables
1942 Press FB Temp Hold Int: Normal
This SP sets the interval between temperature samplings for pressure roller
feedback control.
Note: Modes "1" to "5" below refer to the paper type and thickness settings
selected in User Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
[0 to 50/0/5
o
C]
2 Plain: Mode2
3 Plain: Mode3 [0 to 50/5/5
o
C]
4 Plain: Mode4 [0 to 50/15/5
o
C]
5 Plain: Mode5 [0 to 50/0/5
o
C]
1943 Press FB Temp High Temp: Special
This SP sets the high temperature used by pressure roller feedback temperature
control for Custom paper.
Note: Modes "1" to "5" below refer to the paper type and thickness settings
selected in User Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
[0 to 50/0/5
o
C]
2 Plain: Mode2
3 Plain: Mode3
[0 to 50/20/5
o
C]
4 Plain: Mode4
5 Plain: Mode5 [0 to 50/0/5
o
C]