SP1-xxx Feed
D093/D094 2-30 SM Appendix
CPM down control compares the settings from among these three SP codes and
selects the largest value for the paper interval:
SP1940-001 I
SP1940-051 II
SP1940-071 III
91 Paper Interval Step 1
D093: [1 to 10 / 2.1 / 0.1]
D094: [1 to 10 / 6.8 / 0.1]
The thermistors at the center and end of the pressure roller measure the
temperatures.
The temperature at the center of the pressure roller is subtracted from the
temperature at the end of the pressure roller.
If the difference is greater than the setting of SP1940-081, the interval
between sheets of translucent paper is calculated by multiplying the normal
length of the paper and the setting for SP1940-091.
CPM down control compares the settings from among these three SP codes and
selects the largest value for the paper interval:
SP1940-001 I
SP1940-051 II
SP1940-071 III
1941 Press FB Ctrl Switch by Temp Diff
This SP sets the temperature differential that determines when the machine
adjusts for pressure roller feedback control when the difference between the
temperatures of the center and end of the pressure roller is greater than 20°C
(Default: 20).
[0 to 50/20/5]
Example
If this SP is set to "50": and there is a difference between the temperatures at the
center and end of the pressure roller after more than 50 readings, then pressure
roller feedback control shifts to the supplement mode.