SP5-xxx Mode
D093/D094 2-114 SM Appendix
3rd Day of the week. 0: Sunday, 1: Monday
4th
The number of the week for the day selected at the 3rd digit. If “0” is
selected for “Sunday”, for example, and the selected Sunday is the
start of the 2nd week, then input a “2” for this digit.
5th, 6th
The time when the change occurs (24-hour as hex code).
Example: 00:00 (Midnight) = 00, 01:00 (1 a.m.) = 01, and so on.
7th The number of hours to change the time. 1 hour: 1
8th
If the time change is not a whole number (1.5 hours for example),
digit 8 should be 3 (30 minutes).
1
Setting
Enables/disables the settings for 2 and 3.
0: Disable
1: Enable
3
Rule Set (Start)
The start of summer time.
4
Rule Set (End)
The end of summer time.
5401
Access Control DFU
CTL
These SP's store settings that limit uses access to SDK (Software Development
Kit) application data.
103 Default Document ACL
104 Authentication Time
This SP sets the length of time allowed for authentication.
[1 to 255 / 0 / 1] (0 = 60 sec. standard)
162 Extend Certification
200 SDK1 Unique ID "SDK" is the "Software Development

Table of Contents