Common Procedures
SM 5-7 D093/D094
Replacement
and
Adjustment
5.1.7 RAISING AND LOCKING THE SCANNER UNIT
1. Remove the original feed unit. (
p.5-6 "Removing the Original Feed Unit")
2. Loosen spring [A] and remove the scanner motor belt [B].
3. Tighten the screw again to make sure that the screw and spring do not fall off.
4. Remove the original table ([C] (
x2).
5. Remove screws
, and raise the scanner unit [D]
6. Put a long screwdriver [E] through the holes to lock the scanner unit in the up position.
Always lock the scanner with a screwdriver when it is in the up position.