Cleaning Points
D093/D094 4-8 SM
Charge Corona Unit
1. Remove the charge corona unit (
p.5-30 "Charge Corona Unit")
2. Use lens paper to clean the grid wires.
3. Remove the grid wires [1].
4. Use lens paper to clean the charge corona wire [2].
5. Remove the wire and clean the casing [3] with dry or water damp cloth.
If you use a damp cloth, use the damp cloth first. Then be sure to wipe the cleaned
area dry with a clean dry cloth.