Main SP Modes
D093/D094 6-26 SM
2804 Corona Wire Cleaning Interval
Sets the interval for charge corona wire cleaning.
Note: The wire is cleaned only when the hot roller temperature is below 50 °C
(122
o
F).
[0 to 6/3/1 step]
0: None (no cleaning)
1: After the main switch is turned on.
2: After 300 m of copies
3: After 600 m of copies
4: After 900 m of copies
5: After 1200 m of copies
6: After 1500 m of copies
2902 Test Pattern
Use these SP's to select and print test patterns. Select one of 25 available test
patterns (1-25).
[0 to 25/0/1]
0: None (default)
0: None 13: 1-dot Vertical Line
1: 1-dot Grid Pattern 14: 2-dot Vertical Line
2: 2-dot Grid Pattern 15: 1-dot Horizontal Line
3: 3-dot Grid Pattern 16: 2-dot Horizontal Line
4: 4-dot Grid Pattern 17: Checkered Flag
5: 5-dot Grid Pattern 18: 1-dot Alternating Dot Pattern
6: 6-dot Grid Pattern 19: 2-dot Alternating Dot Pattern
7: 1-dot Argyle Pattern 20: 4-dot Alternating Dot Pattern
8: 2-dot Argyle Pattern 21: Trimming Area
9: 3-dot Argyle Pattern 22: Full Dot Pattern