SP1-xxx Feed
D093/D094 2-24 SM Appendix
beginning of a cold start, the machine determines that it is in a low temperature
environment
[0 to 50/15/1]
12 Low Temp Mode Setting: Cold Start Hold Time
This SP determines the length of time the machine remains in the low
temperature cold start mode after the machine determines that that it has been
cold started in a low temperature environment. After this time has elapsed,
fusing temperature control will operate with the paper type and thickness
settings (see "Paper Thickness Default Selection" in this section).
[0 to 20 / 7 / 0.5 min.]
13 Low Temp Mode Paper Interval Ratio
This SP sets the size of the gap between sheets of paper while the machine is in
the low temperature environment cold start mode.
[1 to 10 / 3 /0.1 mm]
1938 Upper Limit Temperature Width Switch: Press
This SP switches step control by width on and off. After this SP has been
switched on, the step control by width can be set up with SP1939 002 to 004.
Note:
These settings can be done for each paper type and thickness mode.
Modes "1" to "5" below refer to the paper and thickness settings selected in
User Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
[0 to 1/0/1]
0: Disabled
1: Enabled
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2

Table of Contents