Common Procedures
D093/D094 5-10 SM
5.1.10 ORIGINAL FEED TABLE, ORIGINAL FEED SENSOR COVER
1. Unlock and lift the original feed unit. (
p.5-5 "Unlocking, Opening the Original Unit")
2. Open the upper unit.
3. Side covers (
p.5-2 "Side Covers")
4. Original feed table [A] (
x1, x1)
5. Original feed sensor cover [B] (
x 2)
Re-installation
Make sure both mylars [C] are on the top of the front edge of the exposure glass.