SP4-xxx Scanner
D093/D094 2-104 SM Appendix
2 Position to Switch
Sets the original position where the motor speed adjustment for SP4965-1 starts.
[0 to 200 / 112 / 1 mm]
3 Trailing Edge
Specifies the point 14.5 mm past the original set sensor where the speed of the
original exit motor should be adjusted.
[-1 to 1 / 0 / 0.1%]
4966 Output Scanner Motor Speed
This SP sets the speed of the motor when it is tested with SP5804-201
[8 to 320 / 80 / 0.1 mm/sec.]
4972 Scan Correction
These SP's correct the alignment the image scanned by the CIS. For more, see
SP Adjustments.
1 CIS1-2 Main Scan [0 to 656 / 358 / 0]
2 CIS2 Main Scan
DFU
3 CIS2-3 Main Scan [0 to 656 / 424 / 0]
4 CIS3-4 Main Scan [0 to 656/ 425 / 0]
5 CIS4-5 Main Scan [0 to 656 / 426 / 0]
6 CIS1-2 Sub Scan [0 to 2815 / 620 / 1]
7 CIS2 Sub Scan
DFU
8 CIS2-3 Sub Scan [0 to 2815 / 645 / 1]
9 CIS3-4 Sub Scan [0 to 255 / 26 / 1]
10 CIS4-5 Sub Scan [0 to 2815 / 643 / 1]