SP5-xxx Mode
D093/D094 2-116 SM Appendix
5413 Lockout Setting CTL
1
Lockout On/Off
Switches on/off the lock on the local address book account.
[0 to 1/0/1]
0: Off
1: On
2
Lockout Threshold
Sets a limit on the frequency of lockouts for account lockouts.
[1 to 10/5/1]
3
Cancellation On/Off
Determines whether the system waits the prescribed time for input of a
correct user ID and password after an account lockout has occurred.
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are
entered.
4
Cancellation Time
Determines the length of time that the system waits for correct input of the
user ID and password after a lockout has occurred. This setting is used
only if SP5413-3 is set to "1" (on).
[1 to 999/60/1 min.]