Scanner
D093/D094 5-12 SM
5.2 SCANNER
CLASS 1M LED RADIATION WHEN OPEN DO NOT VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Be sure to turn off the main switche and disconnected the power plug from the power
outlet before beginning any disassembly or adjustment of the scanner unit. This copier
uses a class 1M LED radiation.
LED radiations can seriously damage your eyes.
Blue: Wavelength 452-463 nm and an output 6.9 mW
Green: Wavelength 520-531nm and an output 3.9 mW
Red: Wavelength 629-634 nm and an output 4.8 mW
Do not actuate the safety switches, when the original feed unit is open. (This will turn
on the main power.)
Make sure that the safety switches work correctly after finishing any disassembly or
adjustment of the scanner unit.
Make sure that the original feed unit closes correctly after finishing any disassembly or
adjustment of the scanner unit.