2.5 SP4-XXX SCANNER
4008 Scanner Sub Scan Magnification
Adjusts magnification in the sub scan direction by changing the speed of the main
motor.
[-0.9 to +0.9/0/0.1% step]
4010 Scanner Sub Scan Registration
1 Leading Edge
This SP shifts the leading edge of the scanned image relative to the sub scan
direction.
[-10 to 10/0/ 0.1 mm step]
A higher setting "+" shifts the image down (opposite the sub scan direction).
A lower setting "-" shifts the image up (in the same direction as the sub scan
direction).
2 Trailing Edge
This SP shifts the trailing edge of the scanned image relative to the sub scan
direction.
[-10 to 10/0.0/0.1 mm step]
A higher setting "+" shifts the image down (opposite the sub scan direction).
A lower setting "-" shifts the image up (in the same direction as the sub scan
direction).