SP3-xxx Process Control
D093/D094 2-66 SM Appendix
3920 ID Sensor Pattern Interval
1 Job End
This SP sets the distance between the readings of the previous and next ID
sensor pattern.
[20 to 1000 / 100 / 100 cm]
2 During Job ON/OFF
This setting is for ID sensor pattern reading during print jobs.
[0 to 1 / 1 / 1]
If "0" (OFF) is selected the ID sensor pattern will not be read until the job
ends (this means that the most recent Vsp/Vsg reading at the end of the
previous job is used).
If "On" is selected the ID sensor will read the ID sensor patterns at the
prescribed interval to stabilize toner supply control.
3 During Job
This SP sets the time interval between the readings of the previous and next ID
sensor pattern during a job.
[20 to 2000 / 100 / 10 cm]