Preparation
D093/D094 3-2 SM
The machine will not be directly exposed to reflected heat from a space heater in the
winter.
7. Do not install the machine in an area filled with gases that can cause corrosion.
Never set up the machine where it will be exposed to ammonia fumes.
Ammonia in the surrounding area can cause poor reproduction of filled areas in
images.
If exposing the machine to ammonia in the air cannot be avoided, and if poor
reproduction in filled areas of the images is visible, do SP2201-2 and enter a
setting 50 steps lower than the current setting.
8. Do not install the machine in areas higher than 2,000 m (6,600 ft) above sea level.
9. Put the machine on a strong and level surface.
The floor must be able to support a load of more than 2.94 kPa (300 kgf/m
2
.
10. Do not install the machine in an area where there are frequent strong vibrations.
3.1.2 MINIMUM SPACE REQUIREMENTS
1. Front: 1000 mm (40")
2. Back: 600 mm (23")
3. Right: 600 mm (23")
4. Left: 600 mm (23")

Table of Contents