EasyManua.ls Logo

Ricoh D093 - Upper Limit Temperature: Press Roller

Ricoh D093
779 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Modes
D093/D094 6-12 SM
1935 Upper Limit Temperature: Press Roller
This SP changes the stepped adjustments of SP1932 (Target Temp: Pressure
Roller) by using the sum of the settings of SP1932 (Target Temp: Pressure
Roller) +SP1935 (Press FB Control Steps) as the steps.
Example
If the pressure roller temperature for SP1935-1 is 100oC, the target hot
roller temperature is 195oC ("100" is SP1932, "195" is SP1931).
If the pressure roller temperature 120oC (= "100"+"20", this is
SP1932+SP1935), the target hot roller temperature is 175oC (="195"-"20",
this is SP1931 – SP1934)
If the setting is "0", the temperature settings of SP1931 do not change.
1 Plain: Mode1 [0 to 50/20/5]
2 Plain: Mode2 [0 to 50/25/5]
3 Plain: Mode3 [0 to 50/30/5]
4 Plain: Mode4
[0 to 50/20/5]
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain: Low temp. Mode [0 to 50/0/5]

Table of Contents

Related product manuals