SP1-xxx Feed
D093/D094 2-32 SM Appendix
1944 Press FB Temp Low Temp: Special
This SP sets the low temperature used by pressure roller feedback temperature
control for Custom paper.
Note: Modes "1" to "5" below refer to the paper type and thickness settings
selected in User Tools (see "Paper Thickness Default Selection" in this section).
1 Plain: Mode1
[0 to 50/0/5
o
C]
2 Plain: Mode2
3 Plain: Mode3 [0 to 50/10/5
o
C]
4 Plain: Mode4 [0 to 50/5/5
o
C]
5 Plain: Mode5 [0 to 50/0/5
o
C]
1945 Length Level Setting
These SP's define the Length Levels for the following SP codes:
SP1946 Press FB Stop: Target Temp Diff.
SP1947 Press FB Stop: Time Period
1 Level 1 [1000 to 15000/1300/1 mm]
2 Level 2 [1000 to 15000/3700/1 mm]
3 Level 3 [1000 to 15000/6100/1 mm]
4 Level 4 [1000 to 15000/9100/1 mm]
5 Level 5 [1000 to 15000/12100/1 mm]