Service Call Tables
SM 7-49 D093/D094
Trouble-
Shooting
992 D Erratic SC error
CTL
There was an unusual operation by the software because of:
An incorrect argument in the program.
An incorrect internal parameter.
Work memory not sufficient.
An error occurred that could not be detected by other SC codes.
Turn the main power switch off/on.
Go into the SP mode. Do SP7901 to display details about SC992
(software file name, line number, and variable), and inform your
supervisor of the results.
994 C Operation Panel Management Records Exceeded
CTL
An error occurred because the number of records exceeded the limit for
images managed in the service layer of the firmware. This can occur if
there are too many application screens open on the operation panel.
No action required because this SC does not interfere with operation of
the machine.
997 B Cannot select application function
CTL
An application did not start after the user pushed the correct key on the
operation panel.
Software bug
A RAM or DIMM option required for the application is not installed or
not installed correctly.

Table of Contents