Main SP Modes
D093/D094 6-52 SM
5507 Supply Alarm CTL
1 Paper Supply Alarm
Switches the control call on/off for the paper supply.
[0 to 1/0/1]
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number transfer sheets for each
paper size (A3, A4, B4, B5, DLT, LG, LT, HLT)
3 Toner Supply Alarm
Switches the control call on/off for the toner end.
[0 to 1/0/1]
0: Off, 1: On
If you select “1” the alarm will sound when the main machine detects toner end.
80 Toner Call Timing
This SP switches the toner supply call for @Remote.
[0 to 1 / 0 / 1]
0: Toner replacement. Triggers the alarm when toner should be replaced with
new toner.
1: Toner near-end. The alarm triggers at toner-end or toner near-end.
Note: The “Interval nn" SP's below specify the paper control call interval for the
referenced paper sizes.
[00250 to 10000 / 1000 / 1 Step]