Loading...
SP1-xxx Feed
SM Appendix 2-25 D093/D094
Appendix:
SP Mode
Tables
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
1939 Upper Limit Temperature by Width: Press(ure) Roll(er)
Use these SP's to set up the step control used in the paper type and paper
thickness selections done in the User Tools (see "Paper Thickness Default
Selection" in this section).
Note: First, use SP1938 to select the paper type and mode where the setting is
to apply. Next, select the paper width here.
1 > 611mm [0 to 30 / 20 /5]
2 461-610mm
[0 to 30 / 30 /5]
3 298-460mm
4 > 297mm