PM Tables
SM 4-3 D093/D094
Preventive
Maintenance
Description Q’ty
PM Interval
PM Comments
Metric Feet
1 11.0 36.0 R
T&S Unit Casing, Guides 5.5 18.0 C Lens paper or dry cloth.
Quenching Lamp 5.5 18.0 C Lens paper or dry cloth
ID Sensor 5.5 18.0 C Dry cloth; do SP3001 2 to
initialize the sensor after
you clean it.
Pick-off Pawl 5.5 18.0 C
LPH (LED Print Heads) 5.5 18.0 C Lens paper or clean cloth
and alcohol. (
p.4-9)
After cleaning, touch to
discharge static.
Important: Use no other
chemical cleaners.
Fusing Unit
Hot Roller 1 27.5 90.0 R Replace if necessary.
(
p.5-74)
Fusing Cleaning Roller 1 27.5 90.0 R Always replace with hot
roller. (
p.5-72)
Hot Roller Bushings 1 27.5 90.0 R Always replace with hot
roller. Lubricate with
Barrierta – S552R
(
p.5-74)
Pressure Roller 1 33.0 108.0 R Replace if necessary.
(
p.5-75)
Hot Roller Strippers 5.5 18.0 C Dry cloth.
Pressure Roller Strippers 5.5 18.0 C
Hot Roller Thermistor 11.0 36.0 C
Pressure Roller Thermistor 11.0 36.0 C