Special Adjustments
SM 5-115 D093/D094
Replacement
and
Adjustment
After adjusting
1. Print one more pattern and check CIS 1-2.
2. Repeat these procedures until the image at CIS 1-2 is correct.
3. Do these procedures for the other joints (CIS 2-3, CIS 3-4, CIS 4-5)
The “Effect” column in the table below tells you which area moves with the adjustment,
and which area does not move.
SP4972
CIS Main/Sub Scan Offset Adjustment [0 to 2047/638/1]
Problem Joint Effect
1
Main Scan Offset:
Interval 1-2
CIS 1-2 CIS 1 moves. CIS 2 does not move.
3
Main Scan Offset:
Interval 2-3
CIS 2-3 CIS 3 moves. CIS 2 does not move.
4
Main Scan
Offset :Interval 3-4
CIS 3-4 CIS 4 moves. CIS 3 does not move.
5
Main Scan Offset:
Interval 4-5
CIS 4-5 CIS 5 moves. CIS 4 does not move.
6
Sub Scan Offset:
Interval 1-2
CIS 1-2 CIS 1 moves. CIS 2 does not move.
8
Sub Scan Offset:
Interval 2-3
CIS 2-3 CIS 3 moves. CIS 2 does not move.
9
Sub Scan Offset:
Interval 3-4
CIS 3-4 CIS 4 moves. CIS 3 does not move.
10
Sub Scan Offset:
Interval 4-5
CIS 4-5 CIS 5 moves. CIS 4 does not move.
After completing the CIS adjustments, be sure to reset SP4973 to "2.