SP1-xxx Feed
SM Appendix 2-3 D093/D094
Appendix:
SP Mode
Tables
1105 Fusing Temperature Adjustment
Be sure to switch the main power switch off and on after adjustment.
1 Copy Ready Temperature
Sets the copy ready fusing temperature. The setting is the difference from the
target fusing temperature that is set with SP1931.
[0 to +50/10/1°C]
Copying can start at this temperature before the hot roller reaches its target
temperature (SP1931).
3 Low Power Mode
Sets the copy ready temperature for low power mode.
[80 to 150/90/1°C step]
5
Fusing Temperature Calibration DFU
Calibrates the scale for the fusing temperature settings.
[-10 to +10/0/1°C step]
6
Pressure Temperature Calibration: Center DFU
Calibrates the scale for the pressure temperature control at the center of the
pressure roller.
[-10 to +10/0/1°C step]
7
Pressure Temperature Calibration: Edge DFU
Calibrates the scale for the pressure temperature control at the end of the
pressure roller.
[-10 to +10/0/1°C step]