SP1-xxx Feed
D093/D094 2-18 SM Appendix
1931 Target Temp: Hot Roller
Sets the target fusing temperature of the hot roller. After you adjust these SP's,
you must switch the main power switch off and on.
Important: Modes "1" to "5" below refer to the paper type and thickness
settings selected in User Tools (see "Paper Thickness Default Selection" in this
section).
1 Plain: Mode1
[120 to 220/195/5
o
C] 2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4 [120 to 220/185/5
o
C]
5 Plain: Mode5 [120 to 220/175/5
o
C]
6 Trans.: Mode1 [120 to 220/205/5
o
C]
7 Trans.: Mode2
[120 to 220/195/5
o
C]
8 Trans.: Mode3
9 Trans.: Mode4 [120 to 220/165/5
o
C]
10 Trans.: Mode5 [120 to 220/165/5
o
C]
11 Film: Mode1 [120 to 220/195/5
o
C]
12 Film: Mode2 [120 to 220/190/5
o
C]
13 Film: Mode3
[120 to 220/185/5
o
C]
14 Film: Mode4
15 Film: Mode5 [120 to 220/175/5
o
C]
16 Plain: Low Temp Mode [120 to 220/195/5
o