SP1-xxx Feed
D093/D094 2-34 SM Appendix
1 Length Level 1: Normal [0 to 300/15/1 sec.]
2 Length Level 2: Normal [0 to 300/30/1 sec.]
3 Length Level 3: Normal [0 to 300/45/1 sec.]
4 Length Level 4: Normal [0 to 300/60/1 sec.]
5 Length Level 5: Normal [0 to 300/80/1 sec.]
11 Length Level 1: Cold Start [0 to 300/20/1 sec.]
12 Length Level 2: Cold Start [0 to 300/35/1 sec.]
13 Length Level 3: Cold Start [0 to 300/50/1 sec.]
14 Length Level 4: Cold Start [0 to 300/70/1 sec.]
15 Length Level 5: Cold Start [0 to 300/100/1 sec.]
16 Length Level 0: Cold Start
Normally, pressure roller feedback control does not operate when the paper
length is not prescribed (length = 0). But if copying was started while feedback
control was not operating, during a cold start for example, then feedback control
operates using the setting of this SP code.
[0 to 300/15/1 sec.]
17 Length Level 0: False Start
The target hot roller temperature for a flying start is determined by SP1931. This
SP determines the time limit for the hot roller to reach that target hot roller
temperature.
[0 to 300/20/1 sec.]
18 Standby After Cold Start
This SP sets a time period that prohibits printing to begin even after the hot roller
temperature reaches its target temperature after a cold start. If a job is started
during this time period countdown, the countdown changes to the counts for-11 to
-17 above.
[0 to 300/60/1 sec.]