SP4-xxx Scanner
SM Appendix 2-97 D093/D094
Appendix:
SP Mode
Tables
4 Low Limit
Provides the boundary values to the digital A/E processing address for the
scanned image data.
[0 to 255 / 82 / 1]
5 Start Point
Defines the start position for digital A/E processing of the scanned image data.
[0 to 25.5 / 3 / 0.1 mm]
6 Left Start Point
This SP sets the start position for digital AE processing P-Wind for scanned
image data in the main scan direction (from the center of the orignal as a
reference point), starting at the left side of the original.
[0 to 512/60/0.1 mm]
7 Right Start Point
This SP sets the start position for digital AE processing P-Wind for scanned
image data in the main scan direction (from the center of the orignal as a
reference point), stopping at the right side of the original.
[0 to 512/60/0.1 mm]
8 Shading Correction Target Level Setting
Sets the target level for shading correction.
[0 to 1023 / 360 / 1]