SP5-xxx Mode
D093/D094 2-136 SM Appendix
10
RCG Read Timeout
Sets the length of time (seconds) for the timeout when sent data is written from
the RCG during a call over the @Remote network.
[0 to 100/60/1 sec.]
11
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80
on the @Remote network.
[0 to 1/0/1]
0: No. Access denied
1: Yes. Access granted.
13
RFU Timing
This SP determines how the machine receives forum (RFU: @Remote Forum
Updates) updates.
[0 to 1 / 1/ 1]
0: All forum updates
1: Energy status update only
21
RCG – C Registed
This SP displays the Embedded RC Gate installation end flag.
1: Installation completed
2: Installation not completed
23
Connect Type (N/M)
This SP displays and selects the Embedded RC Gate connection method.
0: Internet connection
1: Dial-up connection
61
Cert. Expire Timing DFU
Proximity of the expiration of the certification.
62
Use Proxy
This SP setting determines if the proxy server is used when the machine
communicates with the service center.