SP5-xxx Mode
D093/D094 2-142 SM Appendix
7 Error due to fax transmission in progress.
8 Other error
9 Line type identification still in progress. Please wait.
153
Selection Dial/Push DFU
Used only for Embedded RC Gate-M to set the telephone number of the
dial-up access point of the line checked with SP5816-151. If a number is
entered, use that number. If a number is not displayed, use the pre-set value
for that country.
154
Outside Line Outgoing Number DFU
Used only for Embedded RC Gate-M to set the number of the PSTN number
to dial out where Embedded RC Gate-M is used with a PBX system. If a
number is set here, the number will be replaced by the number returned by
the successful execution of SP5816-151.
156
Dial Up User Name DFU
This is the user name for dialing at the access point where Embedded RC
Gate-M is used.
Note: Numbers with spaces or # marks appear enclosed with quotation
marks in the user name.
157
Dial Up Password DFU
This is the password for dialing at the access point where Embedded RC
Gate-M is used.
Note: Numbers with spaces or # marks appear enclosed with quotation
marks in the user name.
161
Local Phone Number DFU
This is the number of the local line where Embedded RC Gate-M is
connected. This is the line used to communicate with the Call Center.