SP5-xxx Mode
D093/D094 2-144 SM Appendix
200
Manual Polling
Executes manual polling. Embedded RC Gate periodically polls the
@Remote Gateway by HTTPS. This is called "center polling". Use this SP at
any time to poll the @Remote supply center.
201
Regist: Status
Displays a number that indicates the status of the @Remote service device.
0 Neither the @Remote device nor Embedded RC Gate device are set.
1
The Embedded RC Gate device is being set. Only Box registration is
completed. In this status the Basil unit cannot answer a polling
request.
2
The Embedded RC Gate device is set. In this status the Basil unit
cannot answer a polling request.
3
The @Remote device is being set. In this status the Embedded RC
Gate device cannot be set.
4 The @Remote module has not started.
202
Letter Number
Allows entry of the number of the request needed for the Embedded RC Gate
device.
203
Confirm Execute
Executes the inquiry request to the @Remote CTL URL.