SP7-xxx Data Log
SM Appendix 2-193 D093/D094
Appendix:
SP Mode
Tables
7505
Original Jam Det CTL
Displays the total number of original jams by location. These jams occur
when the original does not activate the sensors.
Display range: 0000 to 9999
Note:
A “Check In” failure occurs when the paper fails to activate the sensor at
the precise time.
A “Check Out” failure occurs when the paper remains at the sensor for
longer than the prescribed time and causes a jam.
The 3rd column in the table below tells you the correct component name
used in the service manual.
Operation Panel Display
1 Org at Power On
2 Org Reg Sn: Not On
3 Org Reg Sn/Exit Sn: Both Off
4 Org Reg Sn: Not Off
5 Org Exit Sn: Not Off
6 Org Stop
7 Org Exit Sn: Not On
8 Org Interval Error
7506 Jam Count by Paper Size CTL
This SP displays the counts for the number of jams by paper size.
Note: In the paper size notations below, "T" means "SEF" (Short Edge Feed).
97 A0T/A1
98 A1T/A2
99 A2T/A3