390
442703/B
Transmissionsectors(Planeviews):
Sectors:180,120,90,60or30°
Pulseforms:
CW(ContinuousWave)transmissions
HFM(HyperbolicFrequencyModulation)transmissions(Thispulsetypeisalso
knownas"chirp".)
Bydefault,theST90hasContinuouswave(CW)andLinearFrequencyModulated
(LFM)transmissionmodesavailable.IfyourST90usesLPT32transceiverboards,you
canchangetheFMpulsetypefromLinearFrequencyModulated(LFM)toHyperbolic
FrequencyModulated(HFM).IfyourST90usesTRX32transceiverboards,only
Continuouswave(CW)andLinearFrequencyModulated(LFM)modesareavailable.
Toseewhichtypeoftransceiverboardsyouhave,seetheTransceiverpageintheBITE
dialogbox.
Reception
Numberofreceiverchannels:384
Gainfunctions:
TVG(TimeVariedGain)
AGC(AutomaticGainControl)
RCG(ReverberationControlledGain)
Digitallters:
Ping-PingFilter
NoiseFilter
FMCorrelationlter
BottomFilter
Echopresentations
Displayresolution:1280x1024pixels(Minimum)
ThevisualqualityoftheST90presentationdependsonthequalityofyourgraphic
adapteranddisplay.Werecommendthatyouusealargedisplaywithresolution
1920x1080.
Palettes:Achoiceofcolourpalettesisavailabletotambientlightconditions.
Beamwidths
Userselectable:Auto,Narrow,NormalorWide
Stabilisation
Rollstabilisation:±20degrees(Automatic)
SimradST90InstallationManual

Table of Contents

Other manuals for Simrad ST90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad ST90 and is the answer not in the manual?

Simrad ST90 Specifications

General IconGeneral
BrandSimrad
ModelST90
CategorySonar
LanguageEnglish

Related product manuals