EasyManua.ls Logo

Simrad ST90 - Verifying the Communication with the Course Gyro

Simrad ST90
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
442703/B
369
Verifyingthecommunicationwiththecoursegyro
Inordertooperatecorrectly,theST90requiresinputfromacoursegyro.Thecurrent
headingisshownonthetopbarifyouhaveenabledthisintheDisplayOptionsdialog
box.Thecommunicationwiththesensoristested.
Prerequisites
Thisprocedureassumesthat:
ThesensorisconnectedtotheST90.Itisswitchedonandinnormaloperation.
Theinterfaceportissetupwiththecorrectcommunicationparameters.
YouarefamiliarwithNMEAandotherrelevantdatagramformats.
Youknowhowtosetuptheparametersforserialandlocalareanetwork(LAN)
communication.
Thevesselisberthedoratsea.
Allrelevantvesseldrawings,installationreportsand/ormeasurementresultsare
available.
TheST90isturnedon,anditisworkingnormally.
Neithertoolsnorinstrumentsarerequired.
Context
Note
TheinputfromacoursegyroisessentialforST90operation.Withouttheinputfroma
coursegyro,theST90willnotbeabletopresentcorrectnavigationalinformation.This
lackofcompensationwillpreventtheST90fromprovidingcorrectechoinformation.
Inmostcasesasuitablecoursegyroisalreadyinstalledonthevessel.Aglobal
positioningsystem(GPS)withacompatibleoutputformatcanalsobeused.
ThepropertiesofeachoftheavailablecommunicationportsaredenedontheI/OSetup
page.TheSensorInstallationpageallowsyourST90tocommunicatewithexternal
sensorsandsystems.Tomakesurethattheinformationfromthe"mostreliable"sensors
areusedbytheST90,usetheSensorCongurationpagetodeneadatagrampriorities.
ThecommunicationparametersdenedforNMEA0183are:
BaudRate:4800b/s
DataBits:8
Parity:None
StopBits:1
Procedure
1OpentheSetupmenu.
Settingtowork